did I damage AVR (honda generator) ?

Home Power - Home Power/Home-Made Power for Off-Grid Living. 

Bookmark this page:  YahooMyWeb Yahoo!  Google Google  Windows Live Favorites Windows Live  del.icio.us del.icio.us  digg digg  Add to Netscape Netscape
Subject Author Date
did I damage AVR (honda generator) ? Mark 07-03-2008
Posted by Mark on July 3, 2008, 7:03 pm
Please log in for more thread options
generator is honda gx390, 6600w / surge 8000, northerntool pro series 8000, unit
has
total running hours under 30.

had it connected to load and suspect the ground post connection wire was not
properly
connected to post at other end, ie. bad ground connection may have caused it to
turn
off.

after running it on about 2000-2500w load for 30 minutes, lights flickered
inside
couple times and then shut off, there were no motors running or starting at the
time,
just couple inside lights, fridge, tv and radio, small a/c unit which uses only
1000w,
nothing else was running.

when I ran to the generator, could detect a faint electric burn odor and now
suspect I
may have damaged the automatic voltage regulator.

it restarted fine (I did not reconnect to load) and I got 240/120 output voltage
from
the connection plug but did not want to put it back on load for fear of making
things
worse (?)

is the AVR easy to diagnose and replace? how sensitive are the hondas or
generators in
having the proper ground post connection, if that was the cause of the shut
down?


Posted by Wade Lippman on July 3, 2008, 7:56 pm
Please log in for more thread options

> generator is honda gx390, 6600w / surge 8000, northerntool pro series
> 8000, unit has total running hours under 30.
First of all, it is apparently a Northerntool with a honda engine, not a
honda generator. Right?

On the three generators I have owned the ground is not connected to
anything, so the generator wouldn't much care about your ground connection.
I believe that is standard on consumer generator; OSHA requires industrial
generators to have the ground connected to the neutral. It should say what
you have on both the generator and the owners manual.
I can't see how a bad ground would affect you in either instance unless you
have a device that sends current to the ground rather then to the neutral;
which would be unusual.

And finally I read through the owner's manual. It doesn't say if the ground
is bonded, nor does it mention having AVR. Are you sure it even has it?
If the fridge and the A/C came on at the same time, that could easily have
caused it to stall.
Good luck.


Posted by Mark on July 3, 2008, 8:31 pm
Please log in for more thread options
Wade Lippman wrote:
> First of all, it is apparently a Northerntool with a honda engine, not a
> honda generator. Right?

right, northerntool pro 8000 with honda gx390

> If the fridge and the A/C came on at the same time, that could easily have
> caused it to stall.

you may be thinking of a conventional ac which this is not (inverter system with
variable speed everything, never exceeds 300 watts at startup, 3 amps)

oddly enough, when I've run it the 1st two weeks since new, ac and fridge have
repeatedly cycled and since ac is an inverter, it never causes a surge unlike
conventional systems, max amps well below 20 with all and generator rated above
30
amps

so everything that was running has stayed running previously (over 20 hours in
one
continous run) and nothing of the sort occurred.




Posted by ransley on July 3, 2008, 8:41 pm
Please log in for more thread options
> Wade Lippman wrote:
> > First of all, it is apparently a Northerntool with a honda engine, not =
a
> > honda =A0generator. =A0Right?
>
> right, northerntool pro 8000 with honda gx390
>
> > If the fridge and the A/C came on at the same time, that could easily h=
ave
> > caused it to stall.
>
> you may be thinking of a conventional ac which this is not (inverter syst=
em with
> variable speed everything, never exceeds 300 watts at startup, 3 amps)
>
> oddly enough, when I've run it the 1st two weeks since new, ac and fridge=
have
> repeatedly cycled and since ac is an inverter, it never causes a surge un=
like
> conventional systems, max amps well below 20 with all and generator rated=
above 30
> amps
>
> so everything that was running has stayed running previously (over 20 hou=
rs in one
> continous run) and nothing of the sort occurred.

How did you measure surge, with a digital meter that records the
peak?, ive seen new friges that use 100w pull 700w surge, and 300w
surge for AC sounds way to low. But its not honda so who knows who
made what as far as quality goes. Was the load balanced with a
transfer panel, how did you hook it up.

Posted by Mark on July 3, 2008, 9:12 pm
Please log in for more thread options
ransley wrote:
> How did you measure surge, with a digital meter that records the
> peak?, ive seen new friges that use 100w pull 700w surge, and 300w
> surge for AC sounds way to low.

the inverter ac definitely runs as I described and is rated 790w max and 7 amps
as it
starts off (yes, compressor is inverter controlled also and fully variable
speed, not
a two or three speed) very slowly and almost never draws more than 450w and 5
amps

fridge is fairly new but even granting that it may pull 700w, shouldn't a honda
gx390
engine rated at 8000 watts, continuous 6600 watts easily handle this? it
certainly has
in the first 20 hours of it's operation and it didn't even speed struggle when
things
cycled on and off.

I also know the full load based on power company having connected a data logger
when
running under utility power and we tested each circuit separately and multiple
circuits simultaneously. The logger recorded spikes just as they occurred within
thousands of a second fraction so am very confident of the total power draw of
everything that is running when I connect generator.


Similar ThreadsPosted
does battery type matter on honda generator? July 4, 2008, 8:11 am
The Honda EU2000i..where to buy it and for how much? January 15, 2008, 8:35 pm
honda eb1100 any opinions? August 18, 2007, 6:47 pm
Does anyone have any experience with the Honda GS series? December 24, 2007, 10:17 pm
That new super quiet Honda EU6500ISA March 10, 2007, 2:43 pm
Honda GC160 engine drowning... November 8, 2007, 1:00 pm
Governor Gear Replacment Honda GX270 March 17, 2007, 2:35 pm
Re: Which Generator and Where to Buy It? January 4, 2008, 7:45 pm
Re: Which Generator and Where to Buy It? January 6, 2008, 4:41 am
Re: Which Generator and Where to Buy It? January 5, 2008, 7:03 am

Contact Us | Privacy Policy
XML SitemapXML Sitemap