Hybrid Car – More Fun with Less Gas

Generac shutting down

register ::  Login Password  :: Lost Password?
please rate
this thread
Posted by Boden on February 27, 2008, 9:46 am
 
My Generac 4000XL (Model 190 gasoline engine) started this morning on
the second pull.  It then ran under about 50% load for at least 30
minutes but shut down spontaneously.

I've restarted it about six times and on each cycle it started on the
first pull, runs smoothly for 1/2 to one minute and then stops.

Fuel tank is full, oil level is correct, low oil pressure light doesn't
  come on, ambient temperature is 31 F, total time on the 4000XL is 262
hours.

The last time it ran, about a month ago, the generator ran for 6 to 8
hours under load without event.

Any suggestions would be appreciated.

Boden

Posted by RW Salnick on February 27, 2008, 10:13 am
 
Boden brought forth on stone tablets:

Look at the fuel filter...

bob

Posted by z on February 27, 2008, 12:50 pm
 @gnus01.u.washington.edu:


doesn't

also make sure the fuel tank is vented -- dono if the vent is on the cap
or where on that gen, but if the vent is off or plugged you might get the
same symptoms


Posted by daestrom on February 27, 2008, 5:13 pm
 

Don't have any experience with that model, but I agree with the others.

One thing, when it dies, does it just cut off immediately, or does it
chug/run/surge.  Usually running out of fuel does the latter, while
immediate shut down with no surging is a sign of ignition system.  FWIW

daestrom


Posted by Boden on February 27, 2008, 5:35 pm
 daestrom wrote:


When it stops it doesn't labor...it just dies, immediately.

Boden

This Thread