Posted by Ron Rosenfeld on August 2, 2005, 9:22 pm
>Ron Rosenfeld wrote:
>>
>>
>>>>For the Outback unit, going from 40V to 60V drops the efficiency from 91.3%
>>>>to 88.4%
>>>
>>>Except for the fact that the manufacturer seems to think that this
>>>inverter should stop working at 42V
>>
>>
>> Not sure where that info comes from. For both the Trace and the Outback,
>> the LBCO (Low Battery Cutoff Voltage) is adjustable. On the Outback it can
>> be set as low as 36V; for the Trace -- 32V.
>>
>>
>> -- ron (off the grid in Downeast Maine)
>Not according to the pdf downloaded from their site.
Really? Which "pdf" and which "site" are you looking at? I looked at the
manuals for the units at the respective manufacturer's web sites. In the
Outback manuals, I saw data for the 12 & 24V unit; for the Trace SW, the
manual shows the 48V unit specifically. (Both are in the Inverter setup
section).
For the Outback 12V: "This setting has a range between 9.0 vdc and
12.0 vdc in 0.1 vdc increments."
For the 24V: "This setting has a range between 18.0 vdc and
24.0 vdc in 0.2 vdc increments."
Did you find something that stated the LBCO for a 48V unit would be other
than "a range between 36.0 vdc and 48.0 vdc in 0.4 vdc increments" ??
For the Trace SW units, for the 48V model Range: 32.0-64.0. Again, this is
directly from the manual.
-- ron (off the grid in Downeast Maine)
Posted by Derek Broughton on August 3, 2005, 10:37 am
Ron Rosenfeld wrote:
> wrote:
>
>>> For both the Trace and the Outback,
>>> the LBCO (Low Battery Cutoff Voltage) is adjustable. On the Outback it
>>> can be set as low as 36V; for the Trace -- 32V.
>>
>>Not according to the pdf downloaded from their site.
>
> Really? Which "pdf" and which "site" are you looking at? I looked at the
> manuals for the units at the respective manufacturer's web sites. In the
> Outback manuals, I saw data for the 12 & 24V unit; for the Trace SW, the
> manual shows the 48V unit specifically. (Both are in the Inverter setup
> section).
...
> For the 24V: "This setting has a range between 18.0 vdc and
> 24.0 vdc in 0.2 vdc increments."
And I can guarantee that, in practice, the 24V is in fact that adjustable.
I have one.
--
derek
Posted by Ron Rosenfeld on August 3, 2005, 3:39 pm
wrote:
>...
>> For the 24V: "This setting has a range between 18.0 vdc and
>> 24.0 vdc in 0.2 vdc increments."
>And I can guarantee that, in practice, the 24V is in fact that adjustable.
>I have one.
And I have an SW5548 which also has the LBCO adjustable as per the manual
which I posted.
I wonder what George was looking at to come up with different values.
-- ron (off the grid in Downeast Maine)
Posted by George Ghio on August 4, 2005, 6:53 am
Ron Rosenfeld wrote:
> wrote:
>
>
>>...
>>
>>>For the 24V: "This setting has a range between 18.0 vdc and
>>>24.0 vdc in 0.2 vdc increments."
>>
>>And I can guarantee that, in practice, the 24V is in fact that adjustable.
>>I have one.
>
>
> And I have an SW5548 which also has the LBCO adjustable as per the manual
> which I posted.
>
> I wonder what George was looking at to come up with different values.
>
>
> -- ron (off the grid in Downeast Maine)
Ron
Can post the PDF spec sheet to you if you want. Or you can get from the
Xantrex / Outback sites. Too simple
Posted by Solar Guppy on August 4, 2005, 8:55 am
George , here is the exact links and pages,
http://www.outbackpower.com/pdfs_manuals/Grid-Tie_manual_7_1.pdf
Page 44 , menu Low Battery Cut-Out
Its listed as 18.0 to 24 Volts DC (for a 24 volts inverter) , so Ron is
correct , its 36 volts for an 48Volt inverter
http://www.xantrex.com/web/id/602/docserve.asp
page 54 of the SW-series manual
Range 32.0 to 64.0 for Low Battery Cutoff
Again , Ron is correct
> Ron Rosenfeld wrote:
>> wrote:
>>
>>
>>>...
>>>
>>>>For the 24V: "This setting has a range between 18.0 vdc and
>>>>24.0 vdc in 0.2 vdc increments."
>>>
>>>And I can guarantee that, in practice, the 24V is in fact that
>>>adjustable. I have one.
>>
>>
>> And I have an SW5548 which also has the LBCO adjustable as per the manual
>> which I posted.
>>
>> I wonder what George was looking at to come up with different values.
>>
>>
>> -- ron (off the grid in Downeast Maine)
> Ron
> Can post the PDF spec sheet to you if you want. Or you can get from the
> Xantrex / Outback sites. Too simple
>>
>>
>>>>For the Outback unit, going from 40V to 60V drops the efficiency from 91.3%
>>>>to 88.4%
>>>
>>>Except for the fact that the manufacturer seems to think that this
>>>inverter should stop working at 42V
>>
>>
>> Not sure where that info comes from. For both the Trace and the Outback,
>> the LBCO (Low Battery Cutoff Voltage) is adjustable. On the Outback it can
>> be set as low as 36V; for the Trace -- 32V.
>>
>>
>> -- ron (off the grid in Downeast Maine)
>Not according to the pdf downloaded from their site.